400 Amp Generac HTS-400 240V 2Pole 1PH Automatic Transfer Switch

Products Details

SKU: 150724

Model: HTS-400

  • New
  • 1 Year / 1,000 Hour Limited Warranty (Whichever comes first)
  • U.L. Listed
  • Dimensions (L\" x W\" x H\"): 36" X 24" X 37.5"
  • 2 Pole
  • Volt
  • Amps: 400
  • Weight (Pounds): 245
  • Enclosure: NEMA 3R
  • Phase: Single Phase
  • Voltage: 120/240 Volt

*FOR USE WITH GUARDIAN ELITE GENERATORS ONLY*

Description:
The Generac HTS Transfer Switch is a \"State of the Art\" Smart Switch designed to operate in conjunction with the Generac H-100 Series generator controller.

The HTS Transfer Switch has a 2 wire RS485 communication link to the generator controller.

The utility voltage is monitored by the HTS along with signal before transfer timing, time delay neutral and inphase transfer.

Switch operation is instigated by the generator controller.

All timers and voltage setpoints are programmable through \"GenLink\" Communications Software.


Standard Features:
• Single coil design, electrically operated and
mechanically held
• Programmable exercise time
• SPDT aux contacts
• Main contacts are silver alloy
• Conformal coating protects the printed circuit board
UL1008 Listed
• Indicating LED’s for switch position, standby
opertating, utility available
• 3 position test switch: Fast Test, Auto, Normal Test
• Arc shutes on main contacts
• Signal before transfer contacts
• Rated to all classes of loads
• Remote start, stop and transfer through GenLink®
Communications Software


Interconnections:
Switches and Indicators:
System Ready LED Standby Operating LED
Switch Position LED’s Utility Available LED
Test Switch Fast Test Switch
Return to Normal Switch Safety Disconnect Switch
Standby Accept Voltage.......................85-95%
Standby Accept Frequency ..................85-95%
Nominal Voltage .................................1 Volt Increments
Allowable Deviation of Utility ...............1-100%
Line Interruption Delay........................1-10 Seconds
Engine Warmup Time .........................1-300 Seconds
Minimum Run Time ............................5-60 Minutes
Return to Utility Timer ........................1-30 Minutes
Engine Cooldown Timer ......................1-30 Minutes
Signal Before Transfer Timer ..............1-30 Seconds
Transfer Type ...................................Inphase Time Delay Neurtal


Specifications may vary. Confirm full specs prior to ordering.

Specifications

Get More Information:
  1. HTSspec4.05.pdf

    File Size: 138.537 Kb


Get Adobe Acrobat Reader